TO ORDER:   303.423.1212           Toll-Free: 1.888.423.1214    
            Fax: 303.423.6071
Impact Devices

12401 W. 49th Avenue

Wheat Ridge, CO  USA  80033-1927

Products

Impact Devices has a record of providing a high quality products utilized in many different applications by our customers around the world. Our solenoids have been employed in the testing of turbines and generators for General Electric and have been used in assembly equipment and robots manufactured in Europe and Canada. Our solenoids are shipped worldwide and we are able to ship a range of quantities. We are committed to quality: we test the product performance of each solenoid and we only use UL recognized components.


The specification sheet below displays the typical information needed to design and manufacture a new solenoid design. Once designed, we model and test new solenoids in our facility in West Carrollton, before shipping them to our customers for application testing. The spec sheet then serves as the documentation for the ongoing manufacturing of that design, once the customer has confirmed that the new product performs to the necessary expectation.




Features

Projected life of 125 million cycles

Quiet actuation ideal for office environment

Interfaces with plastic or metal daisy wheel

Unique patented construction minimizes bounce to precise limits

Lead wire length variable

Simple to install and adjust

Availability

The part number described in this preliminary data sheet is 381814-001.


The unit is designed to accept different size and weight plungers as your requirements may dictate.

Call us for prices and prototype information.


Produced and Protected by US Patents 4,272,748 4,200,401 & 5,527,117


Specifications

Force: .011 to .019 joules at 5 amps typical

Stroke: .150" x 250" travel

Insulation Resistance: 1000 megohms

Dielectric Strength: 500 VRMS

Coil Resistance: 1.9 ohm + .1 chm @ +20 C

Finish: Zinc with black chromate finish

Weight: 1.14 oz. (32g) incl. Plunger. Plunger wt. 14 oz (4.g)



Environmental

Life: 125 million actuations projected

Operating Temperature: + 70 C surface max.

Humidity: 95%

Electrical Hook-up

28 VDC + 5 VDC with 1 to 3.5 ms on time

1/10 duty cycle

4-6 amps constant current

5 watts input procedures an 80 rise at 25 C ambiant. The trial coil temperature should not exceed 105 C (rise plus ambiant)

The solenoid was mounted on a 3" x 3" x 1/8" aluminum plate for test purposes

Current, on time and duty cycle must be controlled to insure that the maximum coil temperature is not exceeded.

Frequency

40 Hz with .150" stroke